added accel and decel time setting

This commit is contained in:
cpu
2026-06-17 11:56:43 +00:00
parent 0a3b11d077
commit 1296806709

View File

@@ -187,6 +187,8 @@ For **1.5kW, 220V, 400Hz** spindle:
| **PD001** | Commands Source | **1** | External Terminal (FOR/REV). | | **PD001** | Commands Source | **1** | External Terminal (FOR/REV). |
| **PD070** | Analog Input | **0** | **0-10V** (Standard for PiBot). | | **PD070** | Analog Input | **0** | **0-10V** (Standard for PiBot). |
| **PD072** | High Analog Freq | **400.0** | Scales the knob so "Max" = 400Hz. | | **PD072** | High Analog Freq | **400.0** | Scales the knob so "Max" = 400Hz. |
| **PD014** | Acceleration Time | **20** | 20 sec. ramp spindle to max RPM |
| **PD015** | Deceleration Time | **20** | 20 sec. decel. spindle to zero RPM |
Set the jumper **J1** to short pins **1** and **2** for using the external power supply (0-10V comming from the PiBot Controller). The onboard potentiometer will be disabled. Set the jumper **J1** to short pins **1** and **2** for using the external power supply (0-10V comming from the PiBot Controller). The onboard potentiometer will be disabled.